IEC in Europe & Asia. NERC Reliability IEC current A protection core is designed to transform a distortion-free signal even well. Calculation for Short Circuit Current Calculation using IEC / IEEE Standard. This report contains the description for calculating the short circuit current using IEEE . IEC Current Transformer – Download as PDF File .pdf), Text File .txt) for the analysis of free and dissolved gases ×ÛÝ êðëççæïçéèô Interpretation of.

Author: Yokora Daigor
Country: Eritrea
Language: English (Spanish)
Genre: Automotive
Published (Last): 27 March 2004
Pages: 361
PDF File Size: 17.69 Mb
ePub File Size: 15.40 Mb
ISBN: 389-1-86914-416-8
Downloads: 21206
Price: Free* [*Free Regsitration Required]
Uploader: Tagul

A current transformer CT is a type of transformer that is used to measure alternating current AC. It produces a current in its secondary which is proportional to the current in its primary. Current transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale the large values of voltage or current to small, standardized values that are easy to handle for instruments and protective relays.

The instrument transformers isolate measurement or protection circuits from the high voltage of the primary system. A current transformer provides a secondary current that is accurately proportional to the current flowing in its primary. The current transformer presents a negligible load to the primary circuit. Current transformers are the current-sensing units of the power system and are used at generating stations, electrical substations, and in industrial and commercial electric power distribution.

Like any transformer, a current transformer has a primary winding, a core and a secondary winding, although some transformers, including current transformers, use an air core. In principle, the only difference between a current transformer and a voltage transformer normal type is that the former is fed with a ‘constant’ current while the latter is fed with a ‘constant’ voltagewhere ‘constant’ has the strict circuit theory meaning.

The alternating current in the primary produces an alternating magnetic field in the core, which then induces an alternating current in the secondary. The primary circuit is largely unaffected by the insertion of the CT.

Accurate current transformers need close coupling between the primary and secondary to ensure that the secondary current is proportional to the primary current over a wide current range. The current in the secondary is the current in the primary assuming a single turn primary divided by the number of turns of the secondary. In the 600044-1 on the right, ‘I’ is the current in the primary, ‘B’ is the magnetic field, ‘N’ is the number of turns on the secondary, and ‘A’ is an AC ammeter.

Current transformers typically consist of a silicon steel ring core wound with many turns of copper wire as shown in the illustration to the right. The conductor carrying the frfe current is passed through the ring.

The CT’s primary, therefore, consists of a single ‘turn’. The primary ‘winding’ may be a permanent part of the current transformer, i. Window-type current transformers are also common, which can have circuit cables run through the middle of an opening in the core to provide a single-turn primary winding. To assist accuracy, the primary conductor should be centered in the aperture.

CTs are specified by their current ratio from primary to secondary. For example, a This ratio can also be used to find the impedance or voltage on one side of the transformer, given the appropriate value at the other side.

Referring the impedance is done simply by multiplying initial secondary impedance value by the current ratio. The secondary winding of a CT can have taps to provide a range of ratios, five taps being common. Current transformer shapes and sizes vary depending on the end user or switch gear manufacturer. Low-voltage single ratio metering current transformers are either a ring type or plastic molded case.

Transformers and reactors | Medium Power Converter Section

Split-core current transformers either have a two-part core or a core with a removable section. This allows the transformer to be placed around a conductor without having to disconnect it first.

Split-core current transformers are typically used in low current measuring instruments, often portable, battery-operated, and hand-held see illustration lower right. Current transformers are used extensively for measuring current and monitoring the operation of the power grid. Along with voltage leads, revenue-grade CTs drive the electrical utility’s watt-hour meter on many larger commercial and industrial supplies. High-voltage current transformers are mounted on porcelain or polymer insulators to isolate them from ground.

  ATTESTATION TRAVAUX QUALIBAT PDF

Some CT configurations slip around the bushing of a high-voltage transformer or circuit breakerwhich automatically centers the conductor inside the CT window. Current transformers can be mounted on the low voltage or high voltage leads of a power transformer. Sometimes a section of a bus bar can be removed to replace a current transformer.

Often, multiple CTs are installed as a “stack” for various uses. For example, protection devices and revenue metering may use separate CTs to provide isolation between metering and protection circuits and allows current transformers with different characteristics accuracy, overload performance to be used for the devices. The burden load impedance should not exceed the specified maximum value to avoid the secondary voltage exceeding the limits for the current transformer. The primary current rating of a current transformer should not be exceeded or the core may enter its non linear region and ultimately saturate.

This would occur near the end of the first half of each half positive and negative of the AC sine wave in the primary and would compromise the accuracy. Current transformers are often used to monitor high currents or currents at high voltages. Technical standards and design practices are used to ensure the safety of installations using current transformers. The secondary of a current transformer should not be disconnected from its burden while current is in the primary, as the secondary will attempt to continue driving current into an effective infinite impedance up to its insulation break-down voltage and thus compromise operator safety.

For certain current transformers, this voltage may reach several kilovolts and may cause arcing. Exceeding the secondary voltage may also degrade the accuracy of the transformer or destroy it.

Energizing a current transformer with an open circuit secondary is equivalent to energizing a voltage transformer normal type with a short circuit secondary. In the first case the secondary tries to produce an infinite voltage and in the second case the secondary tries to produce an infinite current. Both scenarios can be dangerous and damage the transformer.

Accuracy classes for various types of measurement and at standard loads in the secondary circuit burdens are defined in IEC as classes 0. The class designation is an approximate measure of the CT’s accuracy. Errors in phase are also important, especially in power measuring circuits.

Current transformer – Wikipedia

Each class has an allowable maximum phase error for a specified load impedance. Current transformers used for protective relaying also have accuracy requirements at overload currents in excess of the normal rating to ensure accurate performance of relays during system faults. A CT with a rating of 2. The secondary load of a current transformer is termed the “burden” to distinguish it from the primary load.

The burden in a CT metering electrical network is largely resistive impedance presented to its secondary winding.

CTT – Current Transformer Tester (2 & 5 Tap Models)

This means a CT with a burden rating of B These specification diagrams show accuracy parallelograms on fref grid incorporating magnitude and phase angle error scales at the CT’s rated fgee.

Items that contribute to the burden of a current measurement circuit are switch-blocks, meters and intermediate conductors. The most common cause of excess burden impedance is the conductor between the meter and the CT.

When substation meters are located far from the meter cabinets, the excessive length of cable creates a large resistance. The knee-point voltage of a current transformer is the magnitude of the secondary voltage above which the output current ceases to linearly lec the input current within declared accuracy.

In testing, if a voltage is applied across the secondary terminals the magnetizing current will increase in proportion to the applied voltage, until the knee point is reached. The knee-point voltage is less applicable for frwe current transformers as their accuracy is generally much higher but constrained within a very small range of the current transformer rating, typically 1.

However, the concept of knee point voltage is very pertinent to protection current transformers, since they are ifc exposed to fault currents of 20 to 30 times rated current.

Ideally, the primary and secondary currents of a current transformer should be in phase. In practice, this is impossible, but, at normal power frequencies, phase shifts of a few tenths of a degree are achievable, while simpler CTs may have phase shifts up to six degrees.

However, in wattmetersenergy metersand power factor meters, phase shift produces errors. For power and energy measurement, the errors are considered to be negligible at unity power factor but become more significant as the power factor approaches zero.

  JOHNSONITE COVE BASE PDF

At zero power-factor, any indicated power is entirely due to the current transformer’s phase error. Bar-type current transformers have terminals frse source and load connections of the primary circuit, and the body of the current transformer provides insulation between the frde circuit and ground.

By use of oil insulation and porcelain bushings, such transformers can be applied at the highest transmission voltages. Ring-type current transformers are installed over a bus bar or an insulated cable and have only a low level of insulation on the secondary coil.

To 60044–1 non-standard ratios or for other special purposes, more than one turn of the primary cable may be passed through the ring.

Where frer metal shield is present in the cable jacket, it must be terminated so no net sheath current passes through the ring, to ensure accuracy. Current transformers used to sense ground fault zero sequence currents, such as in a three-phase installation, may have three primary conductors passed through the ring.

Only the net unbalanced current produces a secondary fres – frse can be used to detect a fault from an energized conductor to ground. Ring-type transformers usually use dry insulation systems, with a hard rubber or plastic case over 60044- secondary windings. For temporary connections, a split ring-type current transformer can be slipped over a cable without disconnecting it. This type has a laminated iron core, with a hinged section that allows it to be installed over the cable; the core links tree magnetic flux produced by the single turn primary winding to a wound secondary with many turns.

Because the gaps in the frse segment introduce inaccuracy, such devices are not normally used for revenue metering. Current transformers, especially those intended for high voltage substation service, may have multiple taps on their secondary windings, providing several ratios in the same device. This can be done to allow for reduced inventory of spare units, or to allow for load growth in an installation. A high-voltage current transformer may have several secondary windings with the same primary, to allow for separate metering and protection circuits, or for connection to different types of protective devices.

For example, one secondary may be used for branch overcurrent protection, while a second winding may be used in a bus differential protective scheme, and a third winding used for power and current measurement. Specially constructed wideband current transformers are also used usually with an oscilloscope to measure waveforms of high frequency or pulsed currents within pulsed power systems.

Unlike CTs used for power circuitry, wideband CTs are rated in output volts per ampere of primary current. If the burden resistance is much less than inductive impedance of the secondary winding at the measurement frequency then the current in the secondary tracks the primary current and the transformer provides a current output that is proportional to the measured current.

On the other hand, if that condition is not true, then the transformer is inductive and gives a differential output. The Rogowski coil uses this effect and requires an external integrator in order to provide a voltage output that is proportional to the measured current.

Ultimately, depending on client requirements, there are two main standards to which current transformers are designed. Current transformers are used for protection, measurement and control in high-voltage electrical substations and the electrical grid.

Current transformers may be installed inside switchgear or in apparatus bushings, but very often free-standing outdoor current transformers are used. In a switchyard, live tank current transformers have a substantial part of their enclosure energized at the line voltage and must be mounted on insulators. Dead tank current transformers isolate the measured circuit from the enclosure. Live tank CTs are useful because the primary conductor is short, which gives better stability and a higher short-circuit current rating.

The primary of the winding can be evenly distributed around the magnetic core, which gives better performance for overloads and transients.